CUMMINS Diesel Generator
-
PERKINS Diesel Generator
-
RICARDO Diesel Generator
-
YUCHAI Diesel Generator
-
YANGDONG Diesel Generator
-
WEICHAI Diesel Generator
-
Diesel Generator
-
Open Type Generator
-
Silent Type Generator
-
Trailer Type Generator
-
Container Diesel Generator
-
Gas Power Generator
-
Gasoline Power Generator
-
Fog Cannon Sprayer
-
Generator Light Tower
ISO Stable PERKINS Diesel Generator 1000kva 800KW Engine Powered
Contact me for free samples and coupons.
WhatsApp:0086 18588475571
WeChat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xRated Power | 220V,400/220 | Frequency | 50 Hz |
---|---|---|---|
Warranty | 1 Year | Place Of Origin | Shandong, China |
Keyword | 50kw Generator | Certificate | ISO9001,CE |
Name | Diesel Generator | Brand | Perkins |
Control Panel | ComAp | Cooling System | Air/Water Cooled |
Fuel | Diesel | Insulation Class | H/F |
Model | Diesel Generator | Noise Level | Low |
Phase | 3 Phase | Starting System | Electric/Manual |
Type | Generator | Voltage | 400V/230V |
Power | 800kw | ||
Highlight | ISO PERKINS Diesel Generator,Stable PERKINS Diesel Generator,800KW Perkins Engine Generator |
CNMC 1000kva 800KW Genset Perkins Diesel Engine Powered Diesel Generator
Automatic Transmission Switch(ATS) - Optional
ATS cabinet is equipped with unique electronic control system and world famous brand switch, don't need to be driven by motor and gear. this is newly design technology which help the cabinet to meet the highest standard of double-power switch.
Level 4 mechanical/electrical interlock over switches
Indicator with city power, power supply and load condition
Automatic mode/manual mode control panel
Leaving for reserved sufficient room, convenient for cable laying
Automatic switchover time, no more than 7 seconds.
Construction and function
2.1 Control panel description
2.1.1 Three lights indicator shows power status.
2.1.2. ATS cabinet control Panel Option with Manual and Auto function. When switch set at Auto, ATS cabinet will take main power as priority. ATS cabinet will switch to charge main electricity when two power supply at the same time. If main power is off, ATS cabinet will switch to standby power and a signal will be sent to the generator set at the same time. When switch set at manual, press two button to switch the power, and Anto function will not work anymore.
2.2 Composition and control system
The main body composition of the control system uses world famous brand relay sets to inspect the main power and phase supply, to transfer the auto start signal, also to carry out power switch between the main power and standby power.
2.3 The main components and function
The main components adapt world famous switch brand with reliable quality, switching double-headed structure, mechanical and electrical chain, switching connection position display, electromagnetic control mode. At each grade load, switching can be fast and reliable .
Operation
3.1 Properly connected to the main circuit (one line), Power on, observe the instructions of power state.
3.2 Manual operation: press the manual button, when both main power and standby power indicator lights, the main power and standby power exist at the same time. Press main power or standby power button, system will charge the electricity accordingly.
3.3 Automatic: Press the Auto Button, system get into auto state. When the main power or phase off, system will send a start signal to generator set, then it will delay (adjustable time relay) to switch to charge the generators.